Cáp Quang Amour Singlemode HITRONIC HUW1500 4 G 50/125 OM4

  • Giá: Theo size tùy chọn
  • LAPP KABEL HITRONIC® HUW Armoured Universal Cable
  • Số lượng: Báo giá
  •  Hỗ trợ mua hàng: 0392534363
  •  Hỗ trợ skype: skype
  •  Viber/Zalo: - Zalo.me/0392534363
  •  Hotline: 0936834795  Lầu 1. Số 170-170Bis Bùi Thị Xuân, Phường Phạm Ngũ Lão, Quận 1 , TP HCM, Việt Nam
  • Thông tin nhanh về sản phẩm

    Cáp Quang LAPP KABEL (27500404) 4 fibres, 4 Cores, 4 Fiber, 4G 50/125 OM4 Single-mode 
    Universal cable with central loose tube, corrugated steel tape and non-metallic strain relief for applications with extended mechanical stress

    HITRONIC® HUW armoured Universal cabel, stranded loose tubes, corrugated steel tape, LSZH outer sheath; J/A-DQ(ZN)(SR)H

    • CPR: Article number choice under www.lappkabel.com/cpr
    • For indoor and outdoor use
    • cable with corrugated steel tape (CST) for increased mechanical stress

    Cáp Quang Armour Single Mide OM4 LAPP KABEL HITRONIC HUW1500 4 G 50/125 OM4 27600308

Benefits

  • Armouring provides excellent protection
    against high mechanical stress and rodents
  • Flame retardance makes it suitable for indoor and outdoor installations
  • Easy to install due to the compact design, high flexibility, robust sheath and small bending radii
  • Water-resistant

Application range

  • For indoor and outdoor use
  • Campus backbone
  • Industrial environments
  • Methods of Deployment: empty plastic pipes, ducts and trays

Product features

  • Outer sheath flame-retardant and halogen-free
  • Central loose tube with up to 24 fibres
  • Colour-coded fibres
  • Longitudinal watertight
  • Excellent rodent protection

Product Make-up

  • Gel-filled loose tube
  • Water-blocking reinforced glass yarn strain relief
  • Corrugated steel tape armour
  • LSZH outer sheath
  • Colour: green (based on RAL 6018)

Classification

  • ETIM 5.0 Class-ID: EC000034
  • ETIM 5.0 Class-Description: Fibre optic cable

Dimensions

  • Primary coated fibre: 250µm
  • Cable: see table

Core identification code

  • Fibre colour code see
    data sheet

Fibre type

  • GOF – Glass Optical Fibre

Standard designation

  • A/J-DQ(ZN)(SR)H
    U-DQ(ZN)(SR)H

Optical values

  • see data sheet

Optical fibre type

  • Core material: glass
  • Cladding material: glass

Permissible bending radius

  • Static: ≥ 15 x outer diameter
  • Dynamic: ≥ 20 x outer diameter

Permissible tensile force

  • Fixed installation: 1500 N
  • Short-term: 2000 N

Temperature range

  • Fixed installation: -30°C to +70°C
Article number Article designation Fibre type Number of fbres Outer diameter (mm) Weight (kg/km)
Multimode G 50 OM3
27500304 HITRONIC® HUW1500 4G 50/125 OM3 50/125 OM3 4 9,6 88
27500308 HITRONIC® HUW1500 8G 50/125 OM3 50/125 OM3 8 9,6 88
27500312 HITRONIC® HUW1500 12G 50/125 OM3 50/125 OM3 12 9,6 88
27500324 HITRONIC® HUW1500 24G 50/125 OM3 50/125 OM3 24 9,6 88
Multimode G 50 OM2
27500204 HITRONIC® HUW1500 4G 50/125 OM2 50/125 OM2 4 9,6 88
27500208 HITRONIC® HUW1500 8G 50/125 OM2 50/125 OM2 8 9,6 88
27500212 HITRONIC® HUW1500 12G 50/125 OM2 50/125 OM2 12 9,6 88
27500224 HITRONIC® HUW1500 24G 50/125 OM2 50/125 OM2 24 9,6 88
Multimode G 62.5 OM1
27500104 HITRONIC® HUW1500 4G 62.5/125 OM1 62.5/125 OM1 4 9,6 88
27500108 HITRONIC® HUW1500 8G 62.5/125 OM1 62.5/125 OM1 8 9,6 88
27500112 HITRONIC® HUW1500 12G 62.5/125 OM1 62.5/125 OM1 12 9,6 88
27500124 HITRONIC® HUW1500 24G 62.5/125 OM1 62.5/125 OM1 24 9,6 88
Single-mode E 9 OS2
27500904 HITRONIC® HUW1500 4E 9/125 OS2 9/125 OS2 4 9,6 88
27500908 HITRONIC® HUW1500 8E 9/125 OS2 9/125 OS2 8 9,6 88
27500912 HITRONIC® HUW1500 12E 9/125 OS2 9/125 OS2 12 9,6 88
27500924 HITRONIC® HUW1500 24E 9/125 OS2 9/125 OS2 24 9,6 88
27500412 HITRONIC® HUW1500 12G 50/125 OM4 50/125 OM4 12 9,6 88
27500424 HITRONIC® HUW1500 24G 50/125 OM4 50/125 OM4 24 9,6 88

Cáp Quang Amour Singlemode HITRONIC HUW1500 4 G 50/125 OM4

Cáp Quang Amour Singlemode  HITRONIC HUW1500 4 G 50/125 OM4
Cảm ơn bạn đã đánh giá
0 Sao 0 Đánh giá
0/0
Cáp Quang LAPP KABEL (27500404) 4 fibres, 4 Cores, 4 Fiber, 4G 50/125 OM4 Single-mode  Universal cable with central loose tube, corrugated steel tape and non-metallic strain relief for applications...

Sản phẩm khác

CÁP CHO DÂY NỐI THERMOCOUPLE LOẠI K NHIỀU CẶP XOẮN

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
Extension- And Compensating Cables, Multi-Paired

PVC insulated - with and without steel wire armouring resp. foil screen

Design

• Version Y:- Fine-wired conductor alloy- PVC core insulation- Cores twisted into layers- PVC outer diameter

• Version SY:- Design alike Version Y- Additional galvanised steel wire braiding- PVC outer sheath

• Version ST:- Design alike version Y- Cores twisted into pairs, pairs twisted into layers- Aluminium foil screening + drain wire- PVC outer sheath

• Design example for PVC-PVC-S-PVC:- PVC core insulation- PVC inner sheath- Steel wire braiding- PVC outer sheath

• Design example for PVC-ST-PVC:- PVC core insulation- STatic foil screen- PVC outer sheath

• Colour identity codeDIN 43710Negative conductor and outer sheath:Fe/CuNi: blueNiCr/Ni: greenPtRh/Pt: whitePositive conductor: always redIEC 60 584Positive conductor and outer sheath:Fe/CuNi: blackNiCr/Ni: greenPtRh/Pt: orangeNegative conductor: always white

• Extension-conductor alloys are identifiedwith X, e.g. JX (Fe/CuNi)Compensating-conductor alloys areidentified with C, e.g. KCA (NiCr/Ni)

• Cáp thermocoup loai k

CÁP QUANG A-DQ(ZN)B2Y HITRONIC HQN1500

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
Lapp HITRONIC® HQN Outdoor Cable

Outdoor cable with central loose tube and non-metallic strain relief

HITRONIC® HQN outdoor cable with central loose tube, rodent protection, dielectric A-DQ(ZN)B2Y with 4, 8, 12 or 24 fibres

Halogen-free

Mechanical resistance

Low weight

Optimum strain relief

UV-resistant

Waterproof

---DATASHEET---

 

CÁP KHÔNG CHỨA HALOGEN CHỐNG NHIỄU CHỐNG DẦU OLFLEX® CLASSIC 115 CH SF (TP) CẶP XOẮN

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
LAPP OLFLEX® CLASSIC 115 CH SF (TP)
  • Chống cháy theo IEC 60332-1-2 (ngọn lửa lan truyền trên một sợi cáp)
  • Không lan truyền ngọn lửa theo IEC 60332-3-24 tương ứng IEC 60332-3-25
     (Ngọn lửa lan truyền trên cáp dọc hoặc bó dây)
  • Không chứa halogen theo IEC 60754-1 (lượng khí axit halogen)
  • Tính ăn mòn của khí đốt theo IEC 60754-2 (mức độ axit)
  • Mật độ khói thấp theo IEC 61034-2
  • Chống dầu theo tiêu chuẩn EN 50363-4-1 (TM5) và UL OIL RES I và UL OIL RES II
  • Chống tia cực tím và thời tiết theo tiêu chuẩn ISO 4892-2
  • Chống ôzôn theo EN 50396
  •  EN 45545-2 certified for railway/rolling stock

CÁP KHÔNG CHỨA HALOGEN CHỐNG NHIỄU OLFLEX® CLASSIC 115 CH LINH HOẠT, TIẾT KIỆM KHÔNG GIAN

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
LAPP ÖLFLEX® CLASSIC 115 CH
  • Chống cháy theo IEC 60332-1-2 (ngọn lửa lan truyền trên một sợi cáp)
  • Không lan truyền ngọn lửa theo IEC 60332-3-24 tương ứng IEC 60332-3-25 
    (Ngọn lửa lan truyền trên cáp dọc hoặc bó dây)
  • Kiểm tra ngọn lửa cáp UL
  • Không chứa halogen theo IEC 60754-1 (lượng khí axit halogen)
  • Tính ăn mòn của khí đốt theo IEC 60754-2 (mức độ axit)
  • Mật độ khói thấp theo IEC 61034-2
  • Chống dầu theo tiêu chuẩn EN 50363-4-1 (TM5) và UL OIL RES I và UL OIL RES II
  • Chống tia cực tím và thời tiết theo tiêu chuẩn ISO 4892-2
  • Chống ôzôn theo EN 50396
  • Mỏng và nhẹ, tiết kiệm không gian lắp đặt

 

CÁP CAO SU FESTOON, CÁP TRÀNG HOA SÂU ĐO CHO HỆ THỐNG CẨU TRỤC

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
FESTOON CABLE FOR LIFT AND CRANE SYSTEM
  • Cáp Festoon kỹ thuật cao xuất xứ EU, vỏ cáp cao su và được thiết kế dẹt phẳng ngang hoặc lõi tròn thường được gắn móc như sâu đo
  • Ứng dụng trong việc kết nối các thiết bị điện di động có ứng suất cơ học thấp ở nhiệt độ môi trường xung quanh tăng lên, ví dụ như trong các xưởng luyện thép hoặc phòng xông hơi khô, nhưng cũng có thể ở nhiệt độ thấp. Lớp cách nhiệt và vỏ bọc có khả năng chống lại hầu hết các loại dầu, mỡ bôi trơn, axit, dung dịch kiềm và chất oxy hóa. Để lắp đặt cố định trong các ống dẫn được bảo vệ bằng cơ khí. danh cho sử dụng trong nhà và ngoài trời. Vỏ bọc đã nâng cao hiệu suất về độ xé, đứt và độ bền của rãnh (EWKF).
  • Đạt chuẩn chứng nhận HAR của EU

CÁP CHỊU NHIỆT 125 ĐỘ C KHÔNG CHỨA HALOGEN CHỐNG NHIỄU ÖLFLEX® HEAT 125 C MC

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
LAPP ÖLFLEX® HEAT 125 C MC FREE HALOGEN
  • Cáp điều khiển vỏ chịu nhiệt không chứa halogen có giáp chống nhiễu chứng nhận tiêu chuẩn DNV, IEC 60332-3
  • Hiệu suất chịu lửa đặc biệt, dải nhiệt độ từ -55°C đến +125°C
  • Không chứa halogen, chống dầu, không thải ra khí độc khi bị cháy
  • Chậm cháy, ít khói IEC 60332-1-2 & IEC 61034-2
  • Chống UV và Ozone theo ISO 4892-2 và EN 50396
  • < 1.0mm² U0/U 300/500 V
  • >1.5mm² U0/U 450/750 V
  • Cáp mềm lõi sợi đồng tinh khiết 99.9% class 5 linh hoạt
  • 2 Phiên bản lõi màu hoặc lõi đen đánh số thứ tự + dây nối đất