CÁP OLFLEX SERVO 2XSLCH-JB

  • Giá: Theo size tùy chọn
  • LAPP ÖLFLEX® SERVO 2XSLCH-JB
  • Số lượng: Báo giá
  •  Hỗ trợ mua hàng:
  •  Hỗ trợ skype: skype
  •  Viber/Zalo: 0936.834.795 - 0888.743.258 - Zalo.me/0888743258
  •  Hotline: 0936.834.795 - 0888.743.258  Lầu 1. Số 170-170Bis Bùi Thị Xuân, Phường Phạm Ngũ Lão, Quận 1 , TP HCM, Việt Nam
  • Thông tin nhanh về sản phẩm

    MC-optimised motor cable, low-capacitance, double screened and halogen-free with improved fire behaviour

    ÖLFLEX® SERVO 2XSLCH-JB – Motor cable for drives with high electrical power, EMI optimized, double screened and halogen-free.

    • Halogen-free and highly flame-retardant
    • 3+3 symmetry reduces common-mode interference effects and bearing currents

     TẢI DATASHEET HERE

Benefits

  • EMC-compliant installation of power drive systems conforming to EN 61800-3
  • High power transmission for large drives
  • Low capacitance design enables longer cable connection between frequency converter and motor
  • Symmetrical 3+3 Version supports the reduction of damaging bearing currents
  • Reduction of flame propagation, density and toxicity of smoke gases in event of fire

Application range

  • Connecting cable between frequency converter and motor
  • In dry, damp or wet interiors
  • Paper industry, automotive industry
  • Food production and packaging machinery
  • Machine tools

Product features

  • Low-capacitance design
  • Fire behaviour:
    – Flame-retardant (IEC 60332-1-2)
    – Halogen-free (IEC 60754-1)
    – No corrosive gases (IEC 60754-2)
    – Low smoke density (IEC 61034-2)
    – Low toxicity (EN 50305)
  • No flame-propagation according to IEC 60332-3-24 respectively IEC 60332-3-25 (Flame spread on vertical cable or wire bundle)

Norm references / Approvals

  • Based on VDE 0276, 0250, 0207

Product Make-up

  • Fine-wire, bare copper conductor
  • Core insulation: XLPE
  • Cores twisted concentrically (symmetrically splitted protective conductor of 3+3 version is gusset-filling divided between the power cores)
  • Screening: wrapping of laminated aluminium foil in combination with tinned copper braiding
  • Outer sheath: Halogen-free special compound, colour black (RAL 9005)

Classification ETIM 5

  • ETIM 5.0 Class-ID: EC000057
  • ETIM 5.0 Class-Description: Low voltage power cable

Classification ETIM 6

  • ETIM 6.0 Class-ID: EC000057
  • ETIM 6.0 Class-Description: Low voltage power cable

Core identification code

  • Colours according to HD 308 S2 VDE 0293-308

Conductor stranding

  • Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5

Minimum bending radius

  • Occasional flexing: 15 x outer diameter
  • Fixed installation: 4 x outer diameter

Nominal voltage

  • U0/U: 600/1000 V

Test voltage

  • Core/Core: 4 kV
  • Core/Screen: 4 kV

Protective conductor

  • G = with GN-YE protective conductor
    X = without protective conductor
  • Protective conductor of 3+3 version is gusset-filling divided between power cores

Temperature range

  • Flexing: -15°C to +90°C
  • Fixed installation: -40°C to +90°C
Article number  Number of cores and mm² per
conductor
Outer diameter [mm]  Copper index (kg/km)  Weight (kg/km)
ÖLFLEX® SERVO 2XSLCH-JB / 4-core version
1133500 4 G 1.5  10.9 95 230
1133501 4 G 2.5  12 150 300
1133502 4 G 4.0  14.5 235 485
1133503 4 G 6.0  16 320 630
1133504 4 G 10.0  18.4 533 860
1133505 4 G 16.0  21 789 1290
1133506 4 G 25.0  25.9 1236 1860
1133507 4 G 35.0  29.3 1662 2610
1133508 4 G 50.0  34.5 2345 2950
1133509 4 G 70.0  38.2 3196 3950
1133510 4 G 95.0  43 4316 5300
1133511 4 G 120.0  47.8 5435 6600
1133512 4 G 150.0  55.7 6394 7043
1133513 4 G 185.0  60.3 7639 8384
ÖLFLEX® SERVO 2XSLCH-JB / 3+3 core version
1133514 3 X 1,5 + 3 G 0,25  11.4 88 140
1133515 3 X 2,5 + 3 G 0,5  12.4 144 220
1133516 3 X 4 + 3 G 0,75  13.9 224 323
1133517 3 X 6 + 3 G 1  15.2 276 420
1133518 3 X 10 + 3 G 1,5  17.2 491 615
1133519 3 X 16 + 3 G 2,5  20.7 723 819
1133520 3 X 25 + 3 G 4  23.8 1136 1325
1133521 3 X 35 + 3 G 6  26.9 1535 1718
1133522 3 X 50 + 3 G 10  31.8 2156 2399
1133523 3 X 70 + 3 G 10  34.6 2871 3056
1133524 3 X 95 + 3 G 16  38.5 3953 4162
1133525 3 X 120 + 3 G 16  42.7 4836 5074
1133526 3 X 150 + 3 G 25  47.8 5412 6128
1133527 3 X 185 + 3 G 35  52.6 7041 7500
1133528 3 X 240 + 3 G 50  61.9 8986 9770

CÁP OLFLEX SERVO 2XSLCH-JB

CÁP OLFLEX SERVO 2XSLCH-JB
Cảm ơn bạn đã đánh giá
5 Sao 5 Đánh giá
5/5
MC-optimised motor cable, low-capacitance, double screened and halogen-free with improved fire behaviour ÖLFLEX® SERVO 2XSLCH-JB – Motor cable for drives with high electrical power, EMI optimized,...

Sản phẩm khác

CÁP CHO DÂY NỐI THERMOCOUPLE LOẠI K NHIỀU CẶP XOẮN

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
Extension- And Compensating Cables, Multi-Paired

PVC insulated - with and without steel wire armouring resp. foil screen

Design

• Version Y:- Fine-wired conductor alloy- PVC core insulation- Cores twisted into layers- PVC outer diameter

• Version SY:- Design alike Version Y- Additional galvanised steel wire braiding- PVC outer sheath

• Version ST:- Design alike version Y- Cores twisted into pairs, pairs twisted into layers- Aluminium foil screening + drain wire- PVC outer sheath

• Design example for PVC-PVC-S-PVC:- PVC core insulation- PVC inner sheath- Steel wire braiding- PVC outer sheath

• Design example for PVC-ST-PVC:- PVC core insulation- STatic foil screen- PVC outer sheath

• Colour identity codeDIN 43710Negative conductor and outer sheath:Fe/CuNi: blueNiCr/Ni: greenPtRh/Pt: whitePositive conductor: always redIEC 60 584Positive conductor and outer sheath:Fe/CuNi: blackNiCr/Ni: greenPtRh/Pt: orangeNegative conductor: always white

• Extension-conductor alloys are identifiedwith X, e.g. JX (Fe/CuNi)Compensating-conductor alloys areidentified with C, e.g. KCA (NiCr/Ni)

• Cáp thermocoup loai k

CÁP QUANG A-DQ(ZN)B2Y HITRONIC HQN1500

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
Lapp HITRONIC® HQN Outdoor Cable

Outdoor cable with central loose tube and non-metallic strain relief

HITRONIC® HQN outdoor cable with central loose tube, rodent protection, dielectric A-DQ(ZN)B2Y with 4, 8, 12 or 24 fibres

Halogen-free

Mechanical resistance

Low weight

Optimum strain relief

UV-resistant

Waterproof

---DATASHEET---

 

CÁP KHÔNG CHỨA HALOGEN CHỐNG NHIỄU CHỐNG DẦU OLFLEX® CLASSIC 115 CH SF (TP) CẶP XOẮN

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
LAPP OLFLEX® CLASSIC 115 CH SF (TP)
  • Chống cháy theo IEC 60332-1-2 (ngọn lửa lan truyền trên một sợi cáp)
  • Không lan truyền ngọn lửa theo IEC 60332-3-24 tương ứng IEC 60332-3-25
     (Ngọn lửa lan truyền trên cáp dọc hoặc bó dây)
  • Không chứa halogen theo IEC 60754-1 (lượng khí axit halogen)
  • Tính ăn mòn của khí đốt theo IEC 60754-2 (mức độ axit)
  • Mật độ khói thấp theo IEC 61034-2
  • Chống dầu theo tiêu chuẩn EN 50363-4-1 (TM5) và UL OIL RES I và UL OIL RES II
  • Chống tia cực tím và thời tiết theo tiêu chuẩn ISO 4892-2
  • Chống ôzôn theo EN 50396
  •  EN 45545-2 certified for railway/rolling stock

CÁP KHÔNG CHỨA HALOGEN CHỐNG NHIỄU OLFLEX® CLASSIC 115 CH LINH HOẠT, TIẾT KIỆM KHÔNG GIAN

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
LAPP ÖLFLEX® CLASSIC 115 CH
  • Chống cháy theo IEC 60332-1-2 (ngọn lửa lan truyền trên một sợi cáp)
  • Không lan truyền ngọn lửa theo IEC 60332-3-24 tương ứng IEC 60332-3-25 
    (Ngọn lửa lan truyền trên cáp dọc hoặc bó dây)
  • Kiểm tra ngọn lửa cáp UL
  • Không chứa halogen theo IEC 60754-1 (lượng khí axit halogen)
  • Tính ăn mòn của khí đốt theo IEC 60754-2 (mức độ axit)
  • Mật độ khói thấp theo IEC 61034-2
  • Chống dầu theo tiêu chuẩn EN 50363-4-1 (TM5) và UL OIL RES I và UL OIL RES II
  • Chống tia cực tím và thời tiết theo tiêu chuẩn ISO 4892-2
  • Chống ôzôn theo EN 50396
  • Mỏng và nhẹ, tiết kiệm không gian lắp đặt

 

CÁP CAO SU FESTOON, CÁP TRÀNG HOA SÂU ĐO CHO HỆ THỐNG CẨU TRỤC

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
FESTOON CABLE FOR LIFT AND CRANE SYSTEM
  • Cáp Festoon kỹ thuật cao xuất xứ EU, vỏ cáp cao su và được thiết kế dẹt phẳng ngang hoặc lõi tròn thường được gắn móc như sâu đo
  • Ứng dụng trong việc kết nối các thiết bị điện di động có ứng suất cơ học thấp ở nhiệt độ môi trường xung quanh tăng lên, ví dụ như trong các xưởng luyện thép hoặc phòng xông hơi khô, nhưng cũng có thể ở nhiệt độ thấp. Lớp cách nhiệt và vỏ bọc có khả năng chống lại hầu hết các loại dầu, mỡ bôi trơn, axit, dung dịch kiềm và chất oxy hóa. Để lắp đặt cố định trong các ống dẫn được bảo vệ bằng cơ khí. danh cho sử dụng trong nhà và ngoài trời. Vỏ bọc đã nâng cao hiệu suất về độ xé, đứt và độ bền của rãnh (EWKF).
  • Đạt chuẩn chứng nhận HAR của EU

CÁP CHỊU NHIỆT 125 ĐỘ C KHÔNG CHỨA HALOGEN CHỐNG NHIỄU ÖLFLEX® HEAT 125 C MC

( Vui lòng bấm vào đây để xem chi tiết giá cho từng size )
LAPP ÖLFLEX® HEAT 125 C MC FREE HALOGEN
  • Cáp điều khiển vỏ chịu nhiệt không chứa halogen có giáp chống nhiễu chứng nhận tiêu chuẩn DNV, IEC 60332-3
  • Hiệu suất chịu lửa đặc biệt, dải nhiệt độ từ -55°C đến +125°C
  • Không chứa halogen, chống dầu, không thải ra khí độc khi bị cháy
  • Chậm cháy, ít khói IEC 60332-1-2 & IEC 61034-2
  • Chống UV và Ozone theo ISO 4892-2 và EN 50396
  • < 1.0mm² U0/U 300/500 V
  • >1.5mm² U0/U 450/750 V
  • Cáp mềm lõi sợi đồng tinh khiết 99.9% class 5 linh hoạt
  • 2 Phiên bản lõi màu hoặc lõi đen đánh số thứ tự + dây nối đất